Re-read, followed to a tee and got everything set right. A search may find a hayward-pool.ca[3] website page that does not have the latest firmware. The only way to return the unit to pre-calibration setting is to "re-calibrate" it. Make sure everything is deenergized and if you arent famaliar with electrical connections have an electician do it. For a better experience, please enable JavaScript in your browser before proceeding. Currently it available for download and installation if needed, but not in Over-the-air updating at this time.[6]. For a better experience, please enable JavaScript in your browser before proceeding. I didn't touch the main power lines going into the box. INSTALLATION AND OPERATION MANUAL PureLink Water Purification System Power Center and Cell Kit Models: APUREM PLC700 PLC1400 H0325600 Re F ENGLISH WARNINGIf these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death. No lights on the controller . Section 3. Hayward has seen some instances where the HUA from a Gen 3 VS pump was not visible to the Omni control.[19]. This is actually brilliant as some screens had such bad calibration that we could not navigate the menu to initiate it. I couldn't do that before R3.2. Control panel and intelliflo keypad don't seem synced? If the available version is higher, then you should upgrade. $99.95 $ 99. This may have been a bug that has since been fixed in a firmware release. Did this time mine so I have circulation. Continue. Once the water temperature is brought to be equal to the set point, nothing will run until the water temperature reaches (set point minus the configured temperature differential) or (set point plus the configured temperature differential). It may not display this or other websites correctly. 4) Click the system restore button. To test the GFCI, push the test button. Tried to find an equivelent but only yhe jandy version has the proper rating. Systems with a solar heater will now have the ability to set the solar temperature separately from the rest of the heaters, allowing people to maximize their free solar heat. JavaScript is disabled. Therefore, the solar set point is disabled by being set equal to the main set point and the operation is the same as normal Auto Mode. there are bunch of ants inside the panel. You will get much more visibility by. My transformer went out too so I stumbled upon this valuable thread (and registered for the site). Going into the Spa configuration and deleting the light feature resolved the issue. COMBUS 7 in the pump connects to terminal 2 on the green plug in the Omnilogic. We are a registered 501(c)3 non-profit that is funded by user donations. Using our free app for your smart phone or web-connected device, you can control all the elements of your pool or pool/spa system, even when you're on the go startxref
Solar heater can now run in cool mode when the cool mode is selected. Note that the system will work in a pool up to 35K gallons which is great if you have a very large pool. They will continue the flash pattern until it associates with the router. As I have found out, the main reason these transformers are so expensive is the 2.5A output. Had to move from Relay Bank HV to Main Panel HV as it was stated that omniDirect only works on main relay HV1-HV4. A member reported[24] the upgrade process as: I found a local hayward dealer and ended up buying: Both had a blue label on the outside (3x5 label with serial# and part #). In Heat Mode, the solar set point must be greater than or equal to the main heater set point. AquaLink RS OneTouch The Finest in Pool and Spa Automation The AquaLink RS OneTouch commands 32 auxiliaries, filtration systems, chemical automation, precision temperature settings, pump speeds, diagnostics, and multiple mood settings for onetouch convenience in a simple, menudriven system. Types of devices that support heating and cooling: Types of devices that support heating only: Controlling Heat/cool via the OmniLogic app requires upgrading to the latest version of the app (4.4.0). I am not sure exactly what parts you need replaced. Checked where transformer was installed. %PDF-1.4
%
125 Satisfied Customers. At $130 a pop, they are't giving these away. I did that on a power supply from a B-52 once and the results weren't pretty, lol. 344 0 obj
<>
endobj
Default Startup Speeds for Valves: Added ability to associate VS filter speeds to valve positions. For a better experience, please enable JavaScript in your browser before proceeding. You can set it to 100% or down to 20% depending on your pool size, usage and needs. One chip on the board U3 slot gets very hot which as a stepdown transformer. Section 1. A check of the transformer showed that it was bad. Only 2 left in stock - order soon. The links below are for helpful Hayward OmniLogic resources: Technical Updates for Pool Professionals shows all the pump models that work with Omni-Based systems. #1 I have been going by the salt readings on my Jandy remote and just noticed that there is a hand written note on the pool control panel that says "Calibrated +700", from the prior owner / maintenance company. Please consider. 6) Pick a restore point (Preferably a date before the issue happened) 7) Wait for the process to finish. Therefore the solar setpoint will move automatically 1F above the main set point to support heat mode. I'd be careful changing transformers for something not OEM. You can also change the langauge from this menu.You will find the TruClear Control Panel to be extremely user friendly and if this is your first salt system you will have no problem setting the chlorine output level to achieve a sparkling blue pool all season.To see my review of the TruClear Salt Water System: https://youtu.be/sGGXD6m4uCsRelated Videos:Controlling a Salt System or Booster Pump with the AUX Relay in a Jandy 2 Hp Vs Pump: https://youtu.be/DshEnnpQVrkEasiest Way to Save Thousands of Dollars on your Pool Cost - Install a Variable Speed Pump! You can check the com bus status from the pump diagnostic menu (Com Bus Online Address:xx). Service Mode will turn off all pool equipment and disable all remote controls including networked devices. I see the two leads coming in from the breaker going to the two posts on the left side but don't know which posts on the right to connect them to. There are three fuses on the motherboard 2 are 4 amp and one 20 amp. If you have an issue getting OmniLogic to recognize a pump HUA note that the low speed bus numbers are read R to L instead of L to R. You should wire the communication in the following order on the LS Bus, 4,3,2,1. Knowing what I would find, I tried the web-page/phone-app to see if I could connect to the remote. Check the fuses. You may find that one of the steps in the OmniLogic Troubleshooting Guide is to clear the DDT - Device Discovery Table - to refresh communications. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. It's AC so does it make a difference? It's good so it it looking more and more like the transformer. HL-Base manufactured after May 14, 2020 will use the new LCD screen with the part number HLX-LCD0520. Also note at the bottom of the Firmwware section it says: When you get the new firmware (at hayward.com/firmware), the first two items in the list are firmware upgrades for the MSP and the MPP. My existing lights were 12v. 6 Dual Speed Pump Relay 7 RS-485 Connections 7.1 Aqualink to Heater "Smart" Communication via RS-485 7.2 Jumpering Jandy ePump RS-485 control 8 iAquaLink Wireless Connectivity 8.1 iAqualink 2.0 Replacement Antenna 8.2 iAqualink iQ-900 Replacement Antenna 8.3 iAqualink Working with Mesh Routers 9 Aqualink LED Light Support Once I got the board back and installed it immediately blew the fuse. In addition, if solar priority is enabled it will turn off the other heaters that are running when the solar heater becomes available. the Spa button is pressed on the AquaLink RS Control Panel, water circulation switches between pool and spa (consult the Jandy JVA Installation Manual to ensure that the JVA's are "in sync" and rotate properly). I would do as Conrad suggests EXCEPT not to use a test strip. 4.4 OneTouch Reset and Display Messages27 4.5 All Button and OneTouch System . Ability to configure multiple chlorinators when using ORP. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. You would use this if you just has a swim party and want to clear up the cloudy pool water. 5.1 Control Panel 19 5.2 Turning Power Pack On/Off (Manually) 19 5.3 Turning Power Pack On/Off . Hello , This is an inactive thread. Brands. Looks a little different than the one i have now (10 years old). In this article I will focus on the Control Panel and how to set the salt level and the other settings. How should I approach to fix it. iAquaLink can be used alone, or combined with the complete line of wall-mounted or wireless AquaLink interfaces. Once you perform the Factory Reset, you'll need to either add and reconfigure all of your system components to the Omni, or you can first try reloading your config and see if that works. OneTouch Controller. For a better experience, please enable JavaScript in your browser before proceeding. All this sound too expensive for nothing to me. If it does make a difference, do I jumper the outside left lead to the inside right and the inside lift lead to the outside right? To erase a configuration or DDT use the Factory Reset option under Service Mode. You should leave it off for at least 48 hours as the salt is circulated in the pool. Not bad for a DIY'er. How does Jandy's freeze protection work? You will get a screen with "???" did a bunch of clicking and finished. You will get a screen with "???" Once power is restored the HUA was visible to the Omni and the pump worked normally. As always, before doing anything as drastic as a Factory Reset, make sure you backup your current config to a USB or your PC. Touch Screen Calibration: Pressing the boot screen for ten seconds during power up enters touch calibration mode. Controlling Auto mode for Heat/cool via the OmniLogic app will require an app upgrade once that feature is released. In order to install firmware, installation files must be on the root directory of the USB drive. Please consider. OmniLogic is capable of sending a digital message over the low voltage line to change light color, but the light has to have the appropriate firmware and hardware to receive the message and act on it to change colors.[23]. Solar prioritization of multiple solar heaters is not supported. Reset breaker or check fuse. Support for the new ENS610EXT Engenius HWLAN bridge. The Jandy Pro Series JXi pool/spa heater is a blower assisted, internal combustion chamber, residential . Well, I got my repaired board back a few hours ago. If you need to replace your OmniLogic with a new one you will then need to add a new site and MSP to the web app. Hayward provides updates for firmware for the following components: With Releasse 4.7.0 the MSP (Main System Processor) update is unified for OmniLogic, OmniPL and OmniHub. Get little boxes in each corner, have to touch them one after the other and finally one in the middle. System Overview. 95. 371 0 obj
<>stream
It looks so beautiful and clean. So this confirms what was stated on this forum about knowing which is good and not. [1] The latest firmware can be found at the Hayward OmniLogic product page[2], Support tab, then scroll down to Omni Firmware. Or go back into the config wizard and you may find the pool had no pump assigned to it. I don't think I'd try jumpering the transformer outputs. Customer Support. After leaving I got a message saying I need new automation system and he will go over the options in email not even in phone call. In your OmniLogic Configuration you tell the Omni system which HUA is for which purpose. %%EOF
You need to copy the two firmware files to a USB drive (at the root level), remove the front panel on the Omni to expose the USB (they should have really mounted this port on the panel in an accessible location! For this version, the heater can be placed in Heat mode or Cool mode. [25] The process is: Hayward has removed the "Shell Command" option in R3.2 and this procedure will no longer work to recalibrate the screen. It is being practiced by thousands of pool owners just like you. JavaScript is disabled. For that price Id drop another couple hundred and get an iaqualink 2.0 kit which includes the suspect board. To turn the system completely off, hold the power button down for 6 seconds. In Cool Mode, the solar set point must be less than or equal to the heater main set point. Service call fee $90. Transformer (model TU62132F0) in the back has 120v going in and only 24v on one yellow wire. The Hayward OmniLogic app can schedule the pool lights. Knowing what I would find, I tried the web-page/phone-app to see if I could connect to the remote. 4.7 out of 5 stars . If you are not on R3.2 - update the firmware to R3.2 before you try anything else. By Kallie Johnson A Jandy AquaLink System helps you maintain your pool settings. If you find an equivelent one let me know, the one in my panel is 120vt primary 24vt 60 va (24vt w/ 2.5 amp capacity is equivelent) let me know. 0000007329 00000 n
Jandy OneTouch Control Panel Series Replacement Parts OneTouch, Faceplate Only, Polished Brass 7987. [17] Based on the picture of the HLPMPCONV board it looks like it connects to the Omni RS-485 bus and the IntelliFlo RS-485 data port. 3.6 Jandy Valve Actuators18 3.7 Auxiliary Power Centers18 3.8 All Button Control Panel Installation..19 3.9 OneTouch Control Panel Installation..20 3.10 Wireless OneTouch Control Panel . The auto update feature will update MSP, MPP, and all smart components to the latest versions. Not picking up my phone now. Release 4.3.2 was released February 2022. If an interlock needs to be modified, it now has the option to edit without having to delete and re-create the interlock. Then you can set your programming to refresh the spa water twice a day and it will not become stagnant. COMBUS 8 in the pump connects to terminal 3 on the green plug in the Omnilogic. User accounts can be created in minutes, used immediately, and the service is free. Solar Heat Priority: Support for solar priority and separate solar setpoint. After installing another fuse and repairing the wiring the pool now works perfectly! The MSP is for the main display on the Omni, and the MPP is for the main board in the Omni. To Boost the chlorine production for 24 hours simply hold down the + and Select arrow keys at the same time. These are replacement parts for the Jandy AquaLink RS and PDA Power Center Boards and Firmware. Had to configure lights through a power cycle scheme to get them into "omniDirect Mode" on the light themselves. I tried to bypass the control relay as you did but the wires are not color coded. This can be used if you have used all the AUX relays and have actuator sockets free. Push the reset button. Get the water/salt tested with an electronic tester. In this video I go over the programming of the Jandy JEP-R Variable-Speed Pump Digital Controller for the Jandy Variable Speed pumps. Related Pool and Spa Questions. Most typical transformers do not include this feature in the design meaning they can fail and send 120vt down the low voltage wire. HUA is Hayward Unique Address that the VS pumps possess. Edit Interlocks: Ability to edit interlocks. The front of the panel says "Aqualink RS" and inside there are a number of buttons but no model number (that I can find). Support. I have been going by the salt readings on my Jandy remote and just noticed that there is a hand written note on the pool control panel that says "Calibrated +700", from the prior owner / maintenance company. 0000003643 00000 n
See my other post for pictures. I had replaced a pool/spa value that wasn't working. A 512MB drive worked for one member while a 32GB drive failed.[5]. If I can get power to my variable speed pump I figured I could use the built in pump timer to cycle the pump on and off each day. Three-phase models only - The phases may be reversed or there may be a loss of phase, call for service. Setting the chlorine output is very simple. 0000004664 00000 n
Freeze protection is a feature that starts the pump when the air temperature approaches freezing, and is usually activated at about 38 degrees Fahrenheit. You are using an out of date browser. To enter the Service Menu simply hold the + and - button down at the same time for 6 seconds. Sensor calibration: Ability to calibrate temperature sensors. Jandy recommends starting a 15K pool at 40% and going up if needed.