1. For a better experience, please enable JavaScript in your browser before proceeding. Now it seems like it is happening every time we run it. I have three of these on my route and two have failed sensors, one has a burned out power sensor. It is being practiced by thousands of pool owners just like you. Can sometimes fix by cleaning off the corrosion. Above Ground Pools, Inground Basins, Pond Portions, Swimming Pool Electric, Pool Pump Motors & Pool Pump Component. Cell current is 85% lower than desired and cell voltage above 19V. $75-100 DIY. This unit has a failed R0452500 OEM Salt Flow/Temperature/Salinity Sensor at the time of this cleaning (Error code 172, 186). I have a service tech coming out to look at the system. Level 2 Code. 2. Toward the end of last season my Jandy/Aquapure Unit started with error code 123. I would say this is a fairly good system except for the expensive sensor failure. The first time it happened, I cleaned the cell and it seemed to settle down for a couple of days. Look for heavy corrosion at both ends. 50 cycle power is common in Europe (note: if the unit detects 60 cycle electric supply then it will default to degrees F for the pool temperature reading). Need help troubleshooting Jandy Aquapure 1400 SWCG. Any new postings here are unlikely to be seen or responded to by other members. Sounds like the circuit board. There are several different error codes that you may encounter with your Jandy Aquapure system, including: Low Salt The "Low Salt" error code indicates that the salt level in your pool is too low for the system to function properly. You will need to go out to the pool equipment and wait for the Aqua Pure to display a 3 digit code, This code will direct you to the problem. Sometimes this works and sometimes it does not. It was 5 years old then. I dissembled the problematic cell and noticed that the center pin of the connector was no longer connected to the electrode inside the cell housing. Clean or replace cell if necessary. If you have the resources I would swap it out with a Pentair Salt system, much more reliable.I do like the Aquapure's power center as it tells you the salt level pretty accurately. WEBSITE: http://www.swimmingpoollearning.com/YouTube Video Index -- A list of all of my videos: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.htmlHere is how to change the Flow Sensor when you get the 171/182 Error code:Jandy- Zodiac Flow Sensor Replacement (Error 172 \u0026 181): http://youtu.be/aWorVrd1GTQSALT WATER POOL CARE:Salt Water Pool Care, Part One- Overview \u0026 Chemistry: http://youtu.be/rUh2kVZJYgcSalt Water Pool Care, Part Two - Adding salt: http://youtu.be/QjrwYWdenhYBRAND SPECIFIC SALT CELL CLEANING VIDEOS:Heavy Calcium Buildup on Salt Cell: http://youtu.be/PGM0A0YUcGUPentair Intellichlor Salt Cell: http://youtu.be/L_6mvl38-1sEcomatic ESC Salt system, troubleshooting: http://youtu.be/3R4uWjb-3oIAquaRite Salt Cell, Hayward AquaRite: http://youtu.be/5NiHio0zsD0Jandy Aquapure 1400 Salt Cell: You are watching it now.Zodiac Salt cell: http://youtu.be/DiEHUduKx2gRELATED VIDEOS:Checking your pools salt level: http://youtu.be/h9VoO2QQpmISalt Cell blowback treatment: http://youtu.be/i7T8VeQQoZAPool Test Kit, 5-way: http://youtu.be/mKD7fphxWJIHigh Alkalinity, lowering Alkalinity in your pool: http://youtu.be/dD7B3QzCNdcConditioner, Cyanuric Acid: http://youtu.be/OLDVjtL2NcQCalculating pool water volume: http://youtu.be/LArc7puehAkNOTES:This is the Jandy 1400 Aqua Pure Salt cell. 13Code174appearsyesCheck flow salinity sensorin relationship to heater orsolar panels. Jandy AquaPure Salt Water Pool Systems deliver high performance and reliable sanitation for swimming pools across the globe. Unit wired to improper AC voltage. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. 194. Our Jandy Aquapure 1400 has started to throw general fault code 120. If one of them is rotted away, it's time for a new cell and cord. It is an easy fix. Generates code 125- The cell s dirty or needs replacement, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. You are using an out of date browser. Level 2 service codes are less common but can be more difficult to diagnose as some issues may cause more than one service code to appear. Your Choice for Swimming Pool Supplies including. I've checked the voltage at the cell and when it is running w/o the. Exactly what the Jandy operators manual says it needs to be. Please consider. It should still be under warranty. Code Number. Just remove the four screws on the Power Center and unplug the old. 145: High Salinity (above 4.0 gpl) - indicates pool needs to be diluted: 170: PIB service condition indicated and is usually caused by low incoming AC voltage - check transformer voltages or for faulty sensors Yes, I do have the Taylor k1766 test kit and I just tested the water and the salt content is at 3600 PPM. As mentioned, it should be under warranty either through your PB or through Jandy directly. Also look inside the cell at the cord end. Contact a pool professional. I had the exact same error codes (alternating 125/194), however my cell was ~4 years old. 5 What does the LCD mean? Troubleshoot your tri-sensor to ensure it is working properly. I changed mine this year took less than 30 min. On power up the AquaPure/PureLink unit: '50' or '60' - The unit is detecting the electrical supply to optimize the unit settings. I purchased a new cell from Marina pools, installed and problem solved. Cell current is 85% lower than desired and cell voltage above 19V. It will be beeping often when it gets this error. Keep your pool system running at top efficiency by understanding the Jandy AquaPure Error Codes with this easy-to-read troubleshooting guide. To keep these units running at top efficiency, the digital controls will display a code when something needs service. Partially drain pool and dilute with fresh water until salinity returns to 3.0 to 3.5 gpl. 60 cycle power is the US standard. Generates code 125- The cell s dirty or needs replacement. It just has some drawbacks that would keep me from recommending this unit.Mrdgvb1 Social Media Links:Google +: https://plus.google.com/b/107735343574734346096/Blogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl You can get the sensor online for about $200.00. To fix this error, you will need to add salt to your pool until the salt level is within the recommended range. You must log in or register to reply here. Pins are clean.. it is a 1400, I will work on getting you a photo of the pins. The sensorlocated to close to the heatsource will cause thiscode.Unit will resumeoperation when theflow sensortemperature dropsbelow 108 degreesCode 175appearswith 182Remove and cleanflow sensor, check forglue on the sensorprobes. Verify proper flow/temperature/salinity sensor installation. If your cell is five years old (about the life of the cell) then you can get a new salt cell kit that comes with the R0452500 sensor for around $700.00.The recommend acid mix for this cell is 5 to 1. LEVEL 2 SERVICE CODES. You will get much more visibility by. The unit is reporting that your Chlorine generator has a problem and needs your attention. I cleaned the cell multiple times and there is no noticeable buildup of scale and the problem continued. JavaScript is disabled. I coordinated the visit with Jandy and their warantee department Will keep ya posted, Hello , This is an inactive thread. We are a registered 501(c)3 non-profit that is funded by user donations. When I get the error codes, go out to the box and press the reset button. The system is roughly 12 years old (came with the house) and began spitting out code 121 and 120 (not at the same time). WEBSITE: http://www.swimmingpoollearning.com/YouTube Video Index -- A list of all of my videos: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-re. It may not display this or other websites correctly. No corrosion, the unit is clean.. its is almost brand new.. only 18 months old. First thing to check is the cord. Jandy AquaPure Electronic Salt Water Chlorinator And INSTALLATION AND OPERATION MANUAL PureLink Water Purification System Power Center and Cell Kit Models: APUREM The three pins go inside and connect to the plates. Cell needs to be cleaned. Five parts water to one part acid. Service Codes: Backwash filter if a DE filter is installed. Troubleshooting Jandy AquaPure Error Codes. After 2 cleanings of the salt cell with acid. It tends to go bad and will give you a 171/182 error code. Its a very simple change out. Check voltage going to the cell. Troubleshoot your tri-sensor to ensure it is working properly. Some error codes, though, will require a licensed professional for proper troubleshooting. Be patient tho, It can take a while for the unit to display this code. So over the last 24 hours or so, the swg has been working intermittently. Order on line, kill the power, couple screws and a couple simple wires to connect. #1 Hi all, I've been fighting with my Jandy Aquapure 700 for a few months. Pool Clown. Put in a warranty claim to your PB. This system also hold the Salinity very well in the pool. I use a 6 to 1 mix on most of my cleanings as to not damage the cell. 1. Multiple presses of the reset button to get the system to work sounds like a software problem?
1811 Lookout Ln, Charlotte, Nc 28205,
What Does A Positive Rpr Blood Test Mean?,
Articles J